ADG506ATQ
Common Product Fields
Part NumberADG506ATQ
ManufacturerAnalog Devices (ADI)
CategoryAll Featured Parts
Description16:1 CMOS Analog Multiplexer, Single/Dual Supply Operation, TTL/5 V CMOS Control, Break-Before-Make Switching, 28-Lead CERDIP, -55°C to +125°C
Supply Status● Available for RFQ
Datasheet
Package28-Lead Ceramic Dual In-Line Package (CERDIP / Q-28) / Through-Hole
RoHSCompliant
Stock Status● Contact for availability
REQUEST QUOTEProduct Overview
The Analog Devices ADG506ATQ is a monolithic CMOS analog multiplexer that connects one of 16 single-ended analog inputs to a common output. Fabricated using the enhanced LC2MOS process, it combines a 16:1 switch network, address decoding, and an enable function for selecting analog signals in multichannel measurement and signal-routing circuits.
Four binary address inputs, A0 through A3, select the required channel. With the enable input high, the addressed input is connected to the common output; with enable low, all channels are disconnected regardless of the address code. The digital controls are compatible with TTL and 5 V CMOS logic, with specified input levels of at least 2.4 V for high and no more than 0.8 V for low.
The device supports single-supply operation with VDD from +10.8 V to +16.5 V and VSS connected to ground. Dual-supply specifications cover VDD from +10.8 V to +16.5 V and VSS from -16.5 V to -10.8 V. The analog signal range extends from VSS to VDD, allowing the selected signal range to follow the applied supply rails.
Typical on-resistance at +25°C is 280 Ω under the specified dual-supply test conditions and 500 Ω under the specified single-supply conditions. On-resistance varies with supply voltage, analog signal level, and temperature. The datasheet provides separate limits and test conditions for the two supply configurations to support evaluation of signal-path loading and accuracy.
Off-state input leakage is typically 20 pA at +25°C under the stated test conditions. For the T version, the specified maximum off-state input leakage is 1 nA at +25°C and 50 nA over the full operating temperature range. This low leakage is useful in precision signal-selection circuits where leakage through unselected channels contributes to measurement error.
Typical channel transition time is 200 ns with dual supplies and 300 ns with a single supply at +25°C. The corresponding maximum limits over the T-grade temperature range are 400 ns and 600 ns. Break-before-make switching disconnects the previously selected channel before connecting the next channel, preventing momentary connections between input signals.
Typical charge injection is 4 pC with source resistance of 0 Ω and signal voltage of 0 V. The supply tables list typical power dissipation of 10 mW, with maximum values of 28 mW for dual-supply operation and 25 mW for single-supply operation under the specified conditions. These characteristics support signal routing with low static power consumption.
The ADG506ATQ is the extended-temperature T version in the Q-28 package and is specified for operation from -55°C to +125°C. Its 28-lead CERDIP construction provides a ceramic through-hole package for board-level installation. The combination of 16-channel selection, logic-compatible controls, and single- or dual-supply operation supports equipment requiring analog multiplexing across an extended temperature range.
Request Quote / RFQ